Yield Strength (0.2% offset)
476.82 MPa (Requirement: ≥ 400 MPa)
Ultimate Tensile Strength
576.38 MPa (Requirement: ≥ 490 MPa)
26.46% (Requirement: ≥ 22%)
CVN Impact (All Weld Metal at -30°C)
70.66 Joules (Requirement: ≥ 27 J)
Result: PASS — Tested & certified by National Test House (Government of India). Certificate No. NTH(NR)/NDT/26/20504, ULR No. TC687026900001076F, dated 13 March 2026.